Product information "Circuit-breaker EB2 400/3H 400A, Icu 50kA / Ics 50kA"

Ics: 50kA
Icu: 50kA
Number of poles: 3
Rated current: 400A
Rated voltage: 690V
Setting value Magnetic: 6-12 x In
Thermal setting value: 0.63-1 x In
Skip product gallery

Accessories for circuit-breaker EB2 400/3H 400A, Icu 50kA / Ics 50kA

Terminal cover PRS2 400-630/3 front, for EB2 400-630
Terminal cover PRS2 400-630/3 front, for EB2 400-630

Mounting from above only.

Regular price: CHF 71.6408
Terminal cover PRS2 400-630/3 Cable connections, for EB2 400-630
Terminal cover PRS2 400-630/3 Cable connections, for EB2 400-630

Two-part design for top and bottom.

Regular price: CHF 44.3732
Undervoltage release NA2, 125-630AF, 24VDC, for EB2 125-630
Undervoltage release NA2, 125-630AF, 24VDC, for EB2 125-630

Cannot be installed together with shunt outlet

Regular price: CHF 99.9245
Auxiliary switch, PS2 125-1600AF, 1W, for EB2 125 - 1600
Auxiliary switch, PS2 125-1600AF, 1W, for EB2 125 - 1600

For all EB2 sizes. I = 3A with resistive load with 24VCD/240VAC.

Regular price: CHF 28.9612
Signal switch SS2 125-1600AF, 1W, for EB2 125 - 1600
Signal switch SS2 125-1600AF, 1W, for EB2 125 - 1600

For all EB2 sizes. I = 3A with resistive load with 24VCD/240VAC.

Regular price: CHF 28.7071
Electric motor drive MO2 630, 100 - 240VAC, for EB2 400-630
Electric motor drive MO2 630, 100 - 240VAC, for EB2 400-630

Voltage range 85%-110%. Load current on actuation depending on the applied voltage at 3.5-7 A. As the motorised drive is designed for a short-term load, it must cool down for at least 15 minutes after 10 consecutive on/off switching operations to ensure safe operation.

Regular price: CHF 1,228.8808
Electric motor drive MO2 630, 100 - 240VAC, with reset, for EB2 400-630
Electric motor drive MO2 630, 100 - 240VAC, with reset, for EB2 400-630

Voltage range 85%-110%. Load current on actuation depending on the applied voltage at 3.5-7 A. As the motorised drive is designed for a short-term load, it must cool down for at least 15 minutes after 10 consecutive on/off switching operations to ensure safe operation.

Regular price: CHF 1,320.8369
Skip product gallery

Customers also bought

Circuit-breaker EB2 630/3E 630A, Icu 50kA / Ics 50kA
Circuit-breaker EB2 630/3E 630A, Icu 50kA / Ics 50kA

Regular price: CHF 1,269.4799
Skip product gallery

Customers also viewed

Circuit-breaker compact, EB2S 160/3HA 100A, Icu 40kA / Ics 20kA
Circuit-breaker compact, EB2S 160/3HA 100A, Icu 40kA / Ics 20kA

Regular price: CHF 223.4105
Circuit-breaker EB2 800/3LE 800A, Icu 50kA / Ics 50kA
Circuit-breaker EB2 800/3LE 800A, Icu 50kA / Ics 50kA

Regular price: CHF 1,980.0598
Circuit-breaker EB2 800/3S 630A, Icu 50kA / Ics 50kA
Circuit-breaker EB2 800/3S 630A, Icu 50kA / Ics 50kA

Regular price: CHF 1,195.5078