The 3-phase bidirectional meter EMU Professional 3/100 for DIN rail mounting has four S0 pulse outputs and is suitable for energy management in accordance with ISO 50001 and energy cost billing. - DIN rail three-phase meter for direct connection - Bidirectional meter - 4x S0 pulse output (active energy supply, active energy consumption, reactive energy) - MID B+D approval for energy cost billing - Suitable for energy management in accordance with ISO 50001 - 2-tariff (day / night), tariff switching via 230V signal - Graphic display for easy reading and configuration Key technical data: Top-hat rail three-phase meter, bidirectional meter for supply and consumption 3x230/400V, 5(100)A, 50 Hz, accuracy class B (1%) Direct connection up to 100A, installation width: 5 HP (90mm) Illuminated graphic LCD 38x28mm (WxH) MID B+D ex works for billing purposes Retrievable measured values (display + M-Bus interface): Active energy consumption kWh total, tariff 1, tariff 2 Active energy supply kWh total, tariff 1, tariff 2 Reactive energy kvarh total, tariff 1, tariff 2 Voltage L1 / L2 / L3 Current total and per phase L1 / L2 / L3 Active power total + and per phase L1 / L2 / L3 Reactive power total + and per phase L1 / L2 / L3 Apparent power total + and per phase L1 / L2 / L3 CosPhi L1 / L2 / L3 Mains frequency Hz Configuration: S0 Pulse rate and time e.g.e.g. 1 / 10 / 100 / 1000 / 10,000 pulses per kWh configurable via buttons Metas - Certified

The 3-phase bidirectional meter EMU Professional 3/100 M-Bus for DIN rail mounting has four S0 pulse outputs and is suitable for energy management in accordance with ISO 50001 and energy cost billing. - DIN rail three-phase meter for direct connection - Bidirectional meter - 4x S0 pulse output (active energy supply, active energy consumption, reactive energy) - MID B+D approval for energy cost billing - Suitable for energy management in accordance with ISO 50001 - 2-tariff (day / night), tariff switching via 230V signal - Graphic display for easy reading and configuration Key technical data: Top-hat rail three-phase meter, bidirectional meter for supply and consumption 3x230/400V, 5(100)A, 50 Hz, accuracy class B (1%) Direct connection up to 100A, installation width: 5 HP (90mm) Illuminated graphic LCD 38x28mm (WxH) MID B+D ex works for billing purposes Retrievable measured values (display + M-Bus interface): Active energy consumption kWh total, tariff 1, tariff 2 Active energy supply kWh total, tariff 1, tariff 2 Reactive energy kvarh total, tariff 1, tariff 2 Voltage L1 / L2 / L3 Current total and per phase L1 / L2 / L3 Active power total + and per phase L1 / L2 / L3 Reactive power total + and per phase L1 / L2 / L3 Apparent power total + and per phase L1 / L2 / L3 CosPhi L1 / L2 / L3 Mains frequency Hz Configuration: S0 Pulse rate and time e.g.e.g. 1 / 10 / 100 / 1000 / 10,000 pulses per kWh configurable via buttons Metas - Certified











The EMU Professional 3/5 Modbus 3-phase measuring transformer meter has an integrated RS485 Modbus RTU and ASCII interface and is suitable for energy cost billing and energy management in accordance with ISO 50001. Modbus RTU and ASCII interface The Modbus RTU and ASCII interface is integrated into the EMU Professional 3/5 and protected against dirt and tampering. Modbus RTU (Remote Terminal Unit) transmits the data in binary form. Modbus ASCII transmits the data in ASCII code. The EMU Professional communicates via Modbus at 9,600, 19,200, 38,400, 57,600 and 115,200 baud. Functions at a glance -MID B+D, ex works for billing purposes -Bidirectional three-phase meter with S0 pulse output -3x230/400V -Accuracy class B (1%) -RS485 Modbus RTU interface -High load Opto Power MOSFET S0 pulse output, 5-230V AC or V DC, max. 90 mA -1 or 5 A current transformer connection for up to 20000/5 or 4000/1 A -2 tariff (day / night), tariff switching via 230V signal Measured values can be called up on the energy meter -Active power (kw) -Reactive power (kvar) -Apparent power (kVA) -Current (A) -Active energy consumption (kWh) and delivery (kWh) -Reactive energy inductive (kvarh) and capacitive (kvarh) -Mains frequency (Hz) -Number of voltage failures Adjustable pulse rate and time: -Pulse length in milliseconds: 4 to 250 ms, adjustable in 2 ms increments -Pulse rate per kWh: 0.001, 0.01, 0.1, 1, 10, 100, 1000 or 10000 Current transformer ratio The current transformer ratio can be configured several times via buttons. The service button can be sealed. -Current transformer /1 A 1/1 A to 4,000/1 A in 1 A increments -Current transformer /5 A 5/5 A to 20,000/5 A in 5 A increments Configuration ex works -Transformer connection: 10 pulses/ 120 ms Connection: 3ph. transformer/5 and 1A Interface: Modbus RTU, RS 485 Approval: MID B+D

The 3-phase bidirectional meter EMU Professional 3/75 Modbus for DIN rail mounting has an integrated RS485 Modbus RTU and ASCII interface and is suitable for energy management in accordance with ISO 50001 and for billing energy costs. Modbus RTU and ASCII interface The Modbus RTU and ASCII interface is integrated in the energy meter and protected against dirt and tampering. Modbus RTU (Remote Terminal Unit) transmits the data in binary form. Modbus ASCII transmits the data in ASCII code. The EMU Professional communicates via Modbus at 9,600, 19,200, 38,400, 57,600 and 115,200 baud. Overview of functions -RS485 Modbus interface -Bidirectional three-phase meter with S0 pulse output 3x230/400V -Direct connection up to 75 A -2-tariff (day / night), tariff switching via 230V signal -High load opto power MOSFET S0 pulse output, 5-230V AC -or V DC, max. 90 mA -MID B+D, ex works for billing purposes -Accuracy class B (1%) Retrievable measured values on the energy meter -Reactive power (kvar) -Reactive energy inductive (kvarh) and capacitive (kvarh) -Active power (kw) -Active energy consumption (kWh) and delivery (kWh) -Apparent power (kVA) -Current (A) -Mains frequency (Hz) -Number of power failures Adjustable pulse rate and time: -Pulse rate per kWh: 0.001, 0.01, 0.1, 1, 10, 100, 1000 or 10000 -Pulse length in milliseconds: 4 to 250 ms, adjustable in 2 ms increments Configuration ex works -Direct connection: 1,000 pulses/ 40 ms Connection: 3ph. Direct 75A Interface: Modbus RTU, RS 485 Approval: MID B+D


The EMU Professional II 3/100 M-Bus LP three-phase meter is an energy meter suitable for EEG third-party quantity delimitation, which has MID B+D and PTB-A 50.7 approval. The M-Bus interface in accordance with EN13757-2, -3 (formerly EN1434-3) is integrated in the EMU Professional II 3/100 M-Bus LP and protected against tampering and soiling.

The EMU Professional II 3/5 M-Bus LP measuring transformer meter has an internal 15-minute meter reading memory. The M-Bus interface in accordance with EN13757-2, -3 (formerly EN1434-3) is integrated in the energy meter and protected against soiling and tampering.

The 3-phase EMU Professional II 3/5 TCP/IP LP is an energy meter which is approved in accordance with MID B+D and PTB-A 50.7. This measuring transformer meter has an integrated TCP/IP interface.

The EMU Professional II 3/100 TCP/IP LP is a 3-phase electricity meter with MID B+D and PTB-A 50.7 approval and has an integrated TCP/IP interface.